Graco Monark 236-065 Instructions Manual

Stainless steel, 15:1 ratio sprayers

Advertisement

Quick Links

INSTRUCTIONS-PARTS LIST
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
STAINLESS STEEL, 15:1 RATIO
Monark Sprayers
2700 psi (18.5 MPa, 185 bar) Maximum Fluid Working Pressure
180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure
Part No. 236–065
Wall Mount Pump
With Fluid Regulator
Part No. 236–898
Wall Mount Pump
Without Fluid Regulator
Part No. 236–069
Pail Mounted Pump
With Fluid Regulator
Part No. 236–900
Pail Mounted Pump
Without Fluid Regulator
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
http://www.graco.com
COPYRIGHT 1993, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
308–332
Supersedes Rev. C
First choice when
quality counts.
Rev. D
and PCN D

Advertisement

Table of Contents
loading

Summary of Contents for Graco Monark 236-065

  • Page 1 INSTRUCTIONS-PARTS LIST This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS STAINLESS STEEL, 15:1 RATIO Monark Sprayers 2700 psi (18.5 MPa, 185 bar) Maximum Fluid Working Pressure 180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure Part No.
  • Page 2 Table of Contents Warnings ........Installation .
  • Page 3 INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed into the eyes or onto the skin can also cause serious injury. Fluid injected into the skin might look like just a cut, but it is a serious injury.
  • Page 4 WARNING WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. Refer to Grounding on page 5. If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately.
  • Page 5: Installation

    Grounding WARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4. To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
  • Page 6 Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip- ment. Reference numbers and letters in parentheses refer to the figures and the parts lists on pages 10–13. Accessories mentioned are available from your Graco distributor.
  • Page 7 Typical Installation – Model 236–067 Shown Pump Bleed-Type Master Air Valve (required for pump) Air Supply Line Master Air Valve (for accessories) Air Line Filter Pump Air Regulator G Gun Air Regulator Fluid Drain Valve (required) Fluid Suction Line Fluid Filter Gun Fluid Supply Hose M Gun Air Supply Hose Air-Assisted Airless Spray Gun...
  • Page 8: Operation

    Pressure Relief Procedure WARNING INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure, stop spraying,...
  • Page 9 Slowly open the pump air regulator (10b) until the pump starts. Run the pump slowly until fluid comes from the drain valve (6). Close the drain valve and continue to run the pump until all the air is pushed out of the fluid lines.
  • Page 10 Part No. 236–065 Wall Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 Wall Mount Pump without Fluid Regulator Includes items 1–28, 43–50 See Detail at left. Apply thread sealant to male threads, except at swivel connections. Parts 39 (REF) 1 (REF) 13 (REF)
  • Page 11 Part No. 236–065 Wall Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 Wall Mount Pump without Fluid Regulator Includes items 1–28, 43–50 Ref. Part No. Description 186–727 BRACKET, wall mounting 223–844 MONARK PUMP; stainless steel See 308–106 for parts 223–160 FLUID FILTER;...
  • Page 12 Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 13 (REF) Torque to 25–30 ft–lb (34–41 N.m). Apply thread sealant to male threads, except at swivel connections.
  • Page 13 Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 Ref. Part No. Description 236–244 COVER, pail; stainless steel 223–844 MONARK PUMP; stainless steel See 308–106 for parts 223–160 FLUID FILTER;...
  • Page 14 Notes...
  • Page 15: Technical Data

    Category Maximum working pressure Maximum incoming air pressure Ratio Wetted parts: Pump Wetted parts: Fluid Hose Wetted parts: Fluid Filter Wetted parts: Suction Hose and Tube Wetted parts: Fluid Fittings Manual Change Summary This manual was revised to include the changes from PCN D. Models 236–067 and 236–899 are obsolete and are removed from this manual.
  • Page 16: Graco Warranty

    Graco Warranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.