January 2007
a. Insert the power cable of the fan into its slot on the bottom fan
b. Connect the power cable of the fan to its connector on the
8
Reinstall the add-in boards.
9
Reconnect any cables you disconnected to the add-in boards.
10
Ensure that any cables located near the fans are kept well away
from the fans.
.
11
Replace the upper fan holder foam.
For instructions, see "To replace the upper fan holder foam" on
page 128.
12
Replace the side cover of the server.
13
Reconnect all peripheral device cables and power cord.
14
Power up the server.
703t Server Maintenance and Diagnostics
holder foam, and route the cable as shown in the preceding
diagram.
motherboard.
The connector is keyed so that it can be attached only one way.
Note: The fan closest to the top of the server connects to the
connector labeled sysfan5. The fan closest to the bottom of the
server connects to the connector that is labeled sysfan3.
CAUTION
Risk of equipment damage
If a cable is caught in a fan, the fan will break.
Replacing basic chassis components
137