natural gas requirements:

bottom of unit
regulator 4.0" w.c.
NPT
1/2 CLOSE NIPPLE
INSTALLER SUPPLIED SHUT
OFF VALVE MUST BE EASILY
ACCESSIBLE
NATURAL GAS
installation must confirm with
local codes or in the absence of local codes with
FUEL GAS ANSI Z223.1
total gas consumption:
PSQ30ZRBI = 65,000 btus
PSQ30RBI = 65,000 btus
PSQ40RBI = 90,000 btus
PSQ40RC = 90,000 btus
PSQ52RSBI = 120,000 btus
PSQ52RCSB = 120,000 btus
PSQ52RBI = 130,000 btus
PSQ52RC = 130,000
do this...
Verify the type of gas to be used, either LP (propane), or Natural gas, and
make sure the marking on the appliance rating plate agrees with that of
the supply.
NEVER connect an unregulated gas line
to the appliance!
An installer supplied gas shut-off valve must be installed in an easily
accessible location. All installer-supplied parts must conform to local
codes, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70-1990, and the National Fuel gas Code, ANSI
Z223.1-1988.
All pipe sealants must be an approved type.
All gas connections should be made by a qualified technician and in
accordance with local codes and ordinances. In the absence of local
codes, the installation must comply with the National Fuel Gas Code
ANSI Z223.1-1988. Gas conversion kits are available from the factory.
DO NOT PUT THREADING
When ordering gas conversion kits, please have the model # and gas
COMPOUND ON THESE
THREADS
type (natural or LP) available from your grill.
The appliance and its individual shut-off valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG (3.5 kPa). The
appliance must be isolated from the gas supply piping system by closing
Fig 1
its individual manual shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal to or less than 1/2
PSIG (3.5 kPa). The installation of this appliance must conform with
local codes or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223. 1a-1988. Installation in Canada must be in
accordance with the standard Can 1-b149.1 and/or .2 (installation
code for gas burning appliances and equipment) and local codes.
NATURAL GAS HOOKUP:
Connection: 1/2" NPT male. Operating Pressure: 4.0" W.C.
Supply Pressure: 5" to 14" water column. If in excess of 14" W.C.
a step down regulator is required. Check with your local gas utility
company or with local codes for instructions on installing gas supply
lines. Be sure to check on type and size or run, and how deep to bury
the line. If the gas line is too small, the grill will not function properly.
Any joint sealant used must be an approved type and be resistive to
the actions of LP gases.
AWESOME
TO HOOK-UP THE FITTINGS SUPPLIED WITH THE GRILL:
POWER!
Assemble as shown (Fig.1). Use threading compound on male threads
only. Do not use threading compound on the male end of the 1/2 NPT.
Use second pipe wrench to hold the grill inlet pipe to avoid shifting any
internal gas lines of the grill. Ensure that the regulator arrow points in
the direction of gas flow towards the unit, away from the supply. Do not
forget to place the installer supplied gas valve in an accessible
location.
5