E83: Error reading the programme selector code
E83
Selector position code not envisaged by the configuration data or configuration error
Checks to perform:
Turn the appliance on, turn
the programme selector to
every setting: wait at least
10 seconds on each of the
settings before moving on to
the next one. Is alarm E83
shown again?
Y
E
S
Check for any friction
between the control panel
and the knob.
Is it difficult to turn the knob?
Y
E
S
Repair the coupling between
the control panel/
selector knob.
Repeat the diagnostic
cycle to check for any
further alarms.
E86
Checks to perform:
Replace the display board and run the diagnostic cycle to check for any further alarms.
E87
Checks to perform:
Replace the display board and run the diagnostic cycle to check for any further alarms.
2011 SOE/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics of electronic controls EWM10931
Repeat the diagnostic
cycle to check for any
NO
Replace the display board
and repeat the diagnostic
NO
cycle to check for any
E86: Programme selector configuration error
E87: User Interface microcontroller defective
!
Check that all the connectors are correctly inserted
further alarms.
further alarms.
!
!
Check that all the connectors are correctly inserted
!
!
Check that all the connectors are correctly inserted
!
60/75
If there are burns on the circuit
board, see page 73
If there are burns on the circuit
board, see page 73
If there are burns on the circuit
board, see page 73
599 73 77-37
E83
E86
E87