Electrolux EWM10931 Service Manual page 41

Hide thumbs Also See for EWM10931:
Table of Contents

Advertisement

1) Check the connection blocks (wiring)
and for the presence of any
protruding/kinked terminals.
2) Check for the presence of any
marks/residue/water or detergent
deposits on the motor and where these
come from.
3) Proceed by checking for any
windings/earthed parts or parts with
poor earthing insulation. Use a tester
with a minimum capacity of 40 MΩ:
between each individual terminal and
the motor casing, read ∞ (fig.10).
4) Proceed by checking each individual
winding according to the following
table (fig.11).
A
B
C
D
Fig. 10
2011 SOE/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics of electronic controls EWM10931
How to check three-phase motors
TERMINALS ON
MOTOR TERMINAL
BLOCK
Winding of tachometric
4-5
1-2
Stator winding
2-3
Stator winding
3-1
Stator winding
CONTROLS
C.E.SET.
108÷133
generator
5.0÷5.8
5.0÷5.8
5.0÷5.8
Fig. 11
!
41/75
S = stator
T = tachometric generator
MOTORS
ACC
(SOLE)
ECM
NIDEC
169÷207
85÷98
5.0÷5.8
5.0÷5.8
5.0÷5.8
5.0÷5.8
5.0÷5.8
5.0÷5.8
If there are burns on the circuit
board, see page 73
599 73 77-37