E38: Internal Pressure Chamber Is Clogged - Electrolux EWM10931 Service Manual

Hide thumbs Also See for EWM10931:
Table of Contents

Advertisement

E38
The analogue pressure switch is not able to measure any variation in the water
Checks to perform:
Run the diagnostic
cycle and set
phase 8.
Is the motor running
and the drum not
moving?
Y
E
S
Replace/reposition
the belt and repeat
the diagnostic cycle
to check for any
further alarms.
Fig. 2
2011 SOE/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics of electronic controls EWM10931

E38: Internal pressure chamber is clogged

level for at least 30 secs during drum rotation.
Drain the water from
the tub and check
the internal pressure
chamber and the
NO
pressure switch tube.
Is the system
unobstructed?
-(see fig.2)-
Replace the
analogue pressure
switch and repeat
the diagnostic cycle
to check for any
further alarms.
!
Check that all the connectors are correctly inserted
NO
Y
E
S
!
31/75
Clean the internal
pressure chamber
and/or the pressure
switch tube
(disconnect the tube
and blow into it to
make sure the
system is
unobstructed) .
-(see fig.8)-
Repeat the
diagnostic cycle
to check for any
further alarms.
Fig. 8
If there are burns on the circuit
board, see page 73
599 73 77-37