Sample Sections Of Sel Output - Fortinet FortiGate-5144C Manual

Compatible with fortigate-5000 series
Table of Contents

Advertisement

Shelf Manager CLI
Type: Discrete (0x6f), "Entity Presence" (0x25)
Belongs to entity (0x1e, 99): [FRU # 6]

Sample sections of SEL Output

The active shelf manager moving from M0 to M4 state (active and working):
0x0285: Event: at Jan 1 00:01:46 1970; from:(0x20,0,0); sensor:(0xf0,0); event:0x6f(asserted):
HotSwap: FRU 0 M0->M1, Cause=0x0
0x0286: Event: at Jan 1 00:01:51 1970; from:(0x20,0,0); sensor:(0xf0,0); event:0x6f(asserted):
HotSwap: FRU 0 M1->M2, Cause=0x2
0x0287: Event: at Jan 1 00:01:51 1970; from:(0x20,0,0); sensor:(0xf0,0); event:0x6f(asserted):
HotSwap: FRU 0 M2->M3, Cause=0x1
0x0288: Event: at Jan 1 00:01:52 1970; from:(0x20,0,0); sensor:(0xf0,0); event:0x6f(asserted):
HotSwap: FRU 0 M3->M4, Cause=0x0
Fan #2 in middle Fan Tray is spinning slower than required:
0x018D: Event: at Jan 1 00:02:15 1970; from:(0x10,0,0); sensor:(0x04,10); event:0x1(asserted):
"Upper Critical", Threshold: 0xff, Reading: 0xff
A low voltage warning on the backup battery on shelf manager 1:
0x022C: Event: at Jan 1 23:09:06 2010; from:(0x10,0,0); sensor:(0x02,6); event:0x1(asserted):
"Lower Critical", Threshold: 0xb3, Reading: 0x99
The board in ATCA slot 4 has exceeded the incoming air temperature limit:
0x0080: Event: at Jan 1 00:25:25 1970; from:(0x8e,0,0); sensor:(0x01,12); event:0x1(asserted):
"Upper Critical", 0x09 0xFF 0xFF
The board in ATCA slot 4 has exceeded the CPU board temperature limit:
0x0081: Event: at Jan 1 00:30:40 1970; from:(0x8e,0,0); sensor:(0x01,13); event:0x1(asserted):
"Upper Critical", 0x09 0xFF 0xFF
FortiGate-5144C 6.2.3 Chassis Guide
Fortinet Technologies Inc.
88

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortigate-5000 seriesFortigate-5060

Table of Contents