Fortinet FortiGate-5144C Manual page 69

Compatible with fortigate-5000 series
Table of Contents

Advertisement

Shelf Manager CLI
Byte 26 = Event Source Type = Class of device or type of software that originated the event
l
Byte 27 = Event Severity
l
Byte 28 = Sensor Device byte = Identifies the instance of the device that holds the sensor that generated the event
l
Byte 29 = Sensor Number
l
Sensor number 9 is the hot swap sensor for PEM B:
# clia sensor 20 9
20: LUN: 0, Sensor # 9 ("FRU 7 HOT_SWAP")
Type: Discrete (0x6f), "Hot Swap" (0xf0)
Belongs to entity: (0xa, 97) [FRU # 7]
No. Time Source Destination Protocol Info
1 17:11:21.469567 192.168.181.66 192.168.182.86 SNMP trap
Frame 1 (177 bytes on wire, 177 bytes captured)
Ethernet II, Src: RapidCit_5f:cc:97 (00:e0:16:5f:cc:97), Dst: Vmware_3c:55:c0
(00:0c:29:3c:55:c0)
Destination: Vmware_3c:55:c0 (00:0c:29:3c:55:c0)
Source: RapidCit_5f:cc:97 (00:e0:16:5f:cc:97)
Type: IP (0x0800)
Internet Protocol, Src: 192.168.181.66 (192.168.181.66), Dst: 192.168.182.86 (192.168.182.86)
User Datagram Protocol, Src Port: 1024 (1024), Dst Port: snmptrap (162)
Simple Network Management Protocol
version: version-1 (0)
community: public
data: trap (4)
trap
enterprise: 1.3.6.1.4.1.3183.1.1 (SNMPv2-SMI::enterprises.3183.1.1)
agent-addr: internet (0)
internet: 192.168.181.66 (192.168.181.66)
generic-trap: enterpriseSpecific (6)
specific-trap: 15757062
time-stamp: 1975765011
variable-bindings: 1 item
Item
name: 1.3.6.1.4.1.3183.1.1.1 (SNMPv2-SMI::enterprises.3183.1.1.1)
valueType: value (0)
value: simple (4294967295)
simple: string-value (1)
Value: Hex-STRING: 54 FA FC B6 41 50 11 DD 00 80 00 50 C2 3F F0 9A 00 4F 13 C8
Packet bytes :
0000 00 0c 29 3c 55 c0 00 e0 16 5f cc 97 08 00 45 00 ..)<U...._....E.
0010 00 a3 00 00 40 00 3e 11 4f 60 c0 a8 b5 42 c0 a8 ....@.>.O`...B..
0020 b6 56 04 00 00 a2 00 8f 6a 28 30 81 84 02 01 00 .V......j(0.....
0030 04 06 70 75 62 6c 69 63 a4 77 06 09 2b 06 01 04 ..public.w..+...
0040 01 98 6f 01 01 40 04 c0 a8 b5 42 02 01 06 02 04 ..o..@....B.....
0050 00 f0 6f 06 43 04 75 c3 c8 13 30 55 30 53 06 0a ..o.C.u...0U0S..
0060 2b 06 01 04 01 98 6f 01 01 01 04 45 54 fa fc b6 +.....o....ET...
0070 41 50 11 dd 00 80 00 50 c2 3f f0 9a 00 4f 13 c8 AP.....P.?...O..
0080 c3 75 00 00 20 20 02 20 09 00 00 a6 14 07 00 00 .u.. . ........
0090 00 00 00 19 0a 40 00 00 00 00 80 53 01 74 65 73 .....@.....S.tes
00a0 74 20 61 6c 65 72 74 20 6d 65 73 73 61 67 65 00 t alert message.
00b0 c1
Some releases of the Shelf Manager allow selecting between three PET formats. The values are defined as follows:
FortiGate-5144C 6.2.3 Chassis Guide
C3 75 00 00 20 20 02 20 09 00 00 A6 14 07 00 00 00 00 00 19 0A 40 00 00
00 00 80 53 01 74 65 73 74 20 61 6C 65 72 74 20 6D 65 73 73 61 67 65 00
C1
Fortinet Technologies Inc.
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortigate-5000 seriesFortigate-5060

Table of Contents