Shelf Manager CLI
deactivate <addr> <fru_id>
debuglevel [<mask> [<console mask>] ]
dhcp <restart> | <status>
exit
fans <addr> <fru id>
firewall [<info [[[[<channel>]:<LUN>]:<NetFn>]:<command>] | <[all]>> | <stop> | <start>]
fru [<addr> [id=<fru_id> | type=<site_type>]] | [type=<site_type> [/<site_number>]]
frucontrol <addr> <fru_id> <command>
frudata [<addr>] [<fru id>] [<block number>]
frudata shm <N> [<block number>]
frudata <addr> <fru id> <byte offset> <byte_1> [byte2 .. [byte_16]]
frudatar <addr> <fru id> <file name>
frudataw [-s|-d|-p|-l] <addr> <fru id> <file name>
frudataw <-s|-d|-p|-l> -c <addr> <fru id>
fruinfo <addr> <fru_id>
getbootdev <addr> [<fru-id> | <amc-addr>]
getconfigparam [<parameter name>]
getfanlevel <addr> <fru_id>
getfanpolicy [<addr> [<fru_id>]] [-s <addr>|site_type [<fru_id>|site_number]]
getfruledstate [-v] [<addr> [<fru_id> [<LedId>|ALL]]]
gethysteresis [ <addr> [ [ lun: ]<sensor id> | <sensor name> ] ]
gethysteresis [ <addr> -f <fru id> ]
gethysteresis [ <addr> -f amc <amc number> ]
getipmbstate <addr> [<link>]
getlanconf <address> <channel number> <parameter number> | <parameter name>
getlanconfig <channel number> <parameter number> | <parameter name>
getpefconfig <parameter name> | <parameter number> [<set selector>]
getsensoreventenable [ <addr> [ [ lun: ]<sensor_id> | <sensor name>
getsensoreventenable [ <addr> -f <fru id> ]
getsensoreventenable [ <addr> -f amc <amc number> ]
getsolconf <address> <channel number> <parameter number> | <parameter name>
getthreshold [ <addr> [ [ lun: ]<sensor id> | <sensor name> ] ]
getthreshold [ <addr> -f <fru id> ]
getthreshold [ <addr> -f amc <amc number> ]
help [<command>]
ipmc [-v] [-x] [<addr>]
localaddress
minfanlevel <addr> <fru_id> <min fan level>
minfanlevel [<min fan level>]
ping <addr> <count>
ping2 <addr> <count>
ping3 <addr> <fru-id> <count>
poll
quit
sel [clear] [ <addr> [ <number of items> [<number of first item>] ] ]
sel info [<addr>]
sendamc <addr> <amc> [<lun>:]<netfn> <command> [<parameters ...>]
sendcmd <addr> [<lun>:]<netfn> <command> [<parameters ...>]
sensor [ <addr> [ [ lun: ]<sensor id> | <sensor name> ] ]
sensor [ <addr> -f <fru id> ]
sensor [ <addr> -f amc <amc number> ]
sensordata [-t] [-d <state>] [ <addr> [ [ lun: ]<sensor id> | <sensor name> ] ]
sensordata [-t] [-d <state>] [ <addr> -f <fru id> ]
sensordata [-t] [-d <state>] [ <addr> -f amc <amc number> ]
sensorread <addr> [ lun: ]<sensor id>
session [<-v>]
FortiGate-5144C 6.2.3 Chassis Guide
Fortinet Technologies Inc.
] ]
54