Air Filter - Fortinet FortiGate-5144C Manual

Compatible with fortigate-5000 series
Table of Contents

Advertisement

FortiGate-5144C Chassis
The alarm LED reset button activates the alarm cutoff (ACO) state for major, minor, and user-defined alarms. You
cannot reset critical alarms with the alarm LED reset button.
When the ACO state is activated, active alarm LEDs blink and all of the alarm relays are deactivated. The alarm reset
button activates the ACO state but does not clear the alarm completely.
The telco alarm connector (DB-15 male)
Telco alarm connector pin assignment
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Air Filter

The FortiGate-5144C chassis includes a front replaceable air filter that removes dust from intake air and provides static
pressure to achieve uniform airflow. The filter must be installed for the chassis to operate normally. If the air filter is not
locked into place the air filter presence sensors cause an alarm.
FortiGate-5144C 6.2.3 Chassis Guide
Descrption
MinorReset+
MinorReset-
MajorReset+
MajorReset-
CriticalAlarm - NO
Critical Alarm NC
Critical Alarm COM
Minor Alarm NO
Minor Alarm NCT
Minor Alarm COM
Major Alarm NO
Major Alarm NC
Major Alarm COM
Power NO
Power COM