Shelf Manager CLI
90: LUN: 0, Sensor # 9 ("+2.5V CPU 2")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0xbd Processed data: 2.305800 Volts
Lower Critical Threshold, Raw Data: 0xb5 Processed data: 2.208200 Volts
Lower Non-Recoverable Threshold, Raw Data: 0xad Processed data: 2.110600 Volts
Upper Non-Critical Threshold, Raw Data: 0xde Processed data: 2.708400 Volts
Upper Critical Threshold, Raw Data: 0xe6 Processed data: 2.806000 Volts
Upper Non-Recoverable Threshold, Raw Data: 0xee Processed data: 2.903600 Volts
90: LUN: 0, Sensor # 10 ("+1.2V 1")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0x76 Processed data: 1.156400 Volts
Lower Critical Threshold, Raw Data: 0x71 Processed data: 1.107400 Volts
Lower Non-Recoverable Threshold, Raw Data: 0x6c Processed data: 1.058400 Volts
Upper Non-Critical Threshold, Raw Data: 0x80 Processed data: 1.254400 Volts
Upper Critical Threshold, Raw Data: 0x85 Processed data: 1.303400 Volts
Upper Non-Recoverable Threshold, Raw Data: 0x8a Processed data: 1.352400 Volts
90: LUN: 0, Sensor # 11 ("+1.2V 2")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0x76 Processed data: 1.156400 Volts
Lower Critical Threshold, Raw Data: 0x71 Processed data: 1.107400 Volts
Lower Non-Recoverable Threshold, Raw Data: 0x6c Processed data: 1.058400 Volts
Upper Non-Critical Threshold, Raw Data: 0x80 Processed data: 1.254400 Volts
Upper Critical Threshold, Raw Data: 0x85 Processed data: 1.303400 Volts
Upper Non-Recoverable Threshold, Raw Data: 0x8a Processed data: 1.352400 Volts
90: LUN: 0, Sensor # 12 ("Incoming Air-Flo")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x28 Processed data: 40.000000 degrees C
Upper Critical Threshold, Raw Data: 0x2d Processed data: 45.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x32 Processed data: 50.000000 degrees C
90: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x4b Processed data: 75.000000 degrees C
Upper Critical Threshold, Raw Data: 0x51 Processed data: 81.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x55 Processed data: 85.000000 degrees C
90: LUN: 0, Sensor # 14 ("CPU1 Temp")
Type: Threshold (0x01), "Temperature" (0x01)
90: LUN: 0, Sensor # 15 ("CPU2 Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Display threshold sensor values for a specific sensor
Enter the following command to display the threshold for sensor 13, which for the FortiGate-5005FA2 is the CPU board
temperature:
# clia threshold 90 13
Pigeon Point Shelf Manager Command Line Interpreter
90: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x4b Processed data: 75.000000 degrees C
FortiGate-5144C 6.2.3 Chassis Guide