Shelf Manager CLI
Where
<IPMB-address> can be board <board-number> or shm <shelf-manager-number> .
<threshold-type> can be:
upper_non_recoverable (can be abbreviated to unr )
upper_critical (can be abbreviated to uc )
upper_non_critical (can be abbreviated to unc )
lower_non_recoverable (can be abbreviated to lnr )
lower_critical (can be abbreviated to lc )
lower_non_critical (can be abbreviated to lnc )
By default, the target value is specified in real units (for example, in Volts for voltage sensors or in Celsius degrees for
temperature sensors). Option
according to sensor-specific rules).
Using this command you can qualify the sensor number with the logical unit number (LUN) if the target controller
supports sensors on multiple LUNs.
command applies to the sensor with the specified sensor number on the lowest LUN. (For example, if the command
specifies sensor 3 without explicit LUN qualification, and the target controller exposes sensor 3 on LUN 1 and another
sensor 3 on LUN 3, the command is applied to the sensor 3 on LUN 1.)
This command can also be issued on the backup Shelf Manager; in that case, threshold values can only be set for
sensors that are local to the backup Shelf Manager.
Use the following example to set the upper non-critical threshold value for the temperature sensor "emulated temp" on
IPM controller 9Chto 99 degrees Celsius.
# clia threshold 9c 2
Pigeon Point Shelf Manager Command Line Interpreter
9c: LUN: 0, Sensor # 2 ("emulated temp")
Type: Threshold (0x01), "Temperature" (0x01)
Lower Non-Critical Threshold, Raw Data: 0x03, Processed Data:
3.000000 degrees C
Lower Critical Threshold, Raw Data: 0x14, Processed Data:
20.000000 degrees C
Lower Non-Recoverable Threshold, Raw Data: 0xfb, Processed
Data: -5.000000 degrees C
Upper Non-Critical Threshold, Raw Data: 0x46, Processed Data:
70.000000 degrees C
Upper Critical Threshold, Raw Data: 0x50, Processed Data:
80.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x5a, Processed
Data: 90.000000 degrees C
# clia setthreshold 9c 0:2 unc 99
Pigeon Point Shelf Manager Command Line Interpreter
Threshold set successfully
# clia threshold 9c 0:2
FortiGate-5144C 6.2.3 Chassis Guide
–r means that a raw value is used instead (usually a byte-size quantity, converted
<lun> can take the value 0, 1 or 3. (LUN 2 is reserved.) If the LUN is omitted, the
Fortinet Technologies Inc.
59