Replacing Temperature Sensors; Figure 9-11 Diode Stack Module - Siemens SINAMICS PERFECT HARMONY GH150 6SL3826 Operating Instructions Manual

Medium-voltage drive
Table of Contents

Advertisement

5. Disconnect and remove the diode from the busbars (D).
6. Only remove the lower bolts at the rectifier module (E).
Installing the diode stack
1. Execute the steps described in Section "Removing the diode stack" in the inverse order.
See also
Removing the diode stack (Page 114)
9.7.9

Replacing temperature sensors

The temperature sensor is located at the rear of the AIC cabinet.
1. Remove the AIC rear panel.
2. Remove the ties from the sensors.
3. Withdraw the sensors from the front of the AIC.
4. Remove the sensors from the Power Stack Adapter.
5. Insert the new sensors
6. Reconnect the sensors.
SINAMICS PERFECT HARMONY GH150 6SL3826
Operating Instructions 05/2020
You can now slide-out the diode stack module and remove it.
Figure 9-11
Diode stack module
– Remove mounted components, e.g. brackets, which are not provided at/on the new
diode stack from the diode stack that you just removed. Mount these parts and
components onto the new diode stack.
– When installing the diode stack, always use new screws, washers and nuts.
– Fix the capacitor cables using cable ties.
Maintenance
9.7 Repair
115

Advertisement