Commissioning; General Information - Rinnai RDV600ER Installation Manual

Hide thumbs Also See for RDV600ER:
Table of Contents

Advertisement

GENERAL INFORMATION

Step 1.
Unpack the Fascia
For commissioning, the control panel located
on the fascia will need to be connected to the
communication cable of the heater engine.
The Fascia Assembly is supplied in a separate
carton, check to ensure you have all the contents
as listed on "CARTON CONTENTS / ITEM
CHECKLIST" on page 4 at the start of this manual
before
proceeding.
materials and check all components for damage.
If ANY damage is evident DO NOT install or
operate this appliance. Contact your supplier for
advice.
Step 2.
Connect Push Button Control
Carefully pick up fascia assembly, and position
the fascia close to the heater engine.
Connect the RJ45 plug (A) into the socket (B)
located on the back of fascia on the bottom left
hand corner, (this connects the push button
control panel via a communications cable to the
heater engine's control box).
Carefully lean the fascia up against a wall, placing the card board carton between the fascia and
the wall will protect both the wall and the fascia from being damaged while completing the heater

commissioning.

HINT
Step 3.
Switch On the Electricity Supply
230 VOLTS, RISK OF ELECTRICAL SHOCK!
Installation and commissioning MUST be carried out ONLY by an Authorised person.
WARNING
Wiring inside this appliance may be at 230V potential, when performing the commissioning, the
appliance electrical power will need to be connected. Exercise CAUTION as there is potential for
electric shock from the exposed wiring and circuitry. DO NOT leave the appliance unattended
when power is connected and the panels are removed.
Step 4.
Commission the Appliance
DO NOT test for gas leakage with an open flame.
The gas type codes and gas pressures for this appliance MUST be checked and set in accordance
WARNING
with these instructions when the appliance is installed, OR after the replacement of any component
or reassembly after service.
Burner gas pressures and gas types are factory set.
The location of the gas control is in the air gap at the lower right hand side of the appliance.
The location of the data plate (C) is on the base plate of the heater engine within the air gap on the right hand side
of the appliance.
Gas supply pressure is to be checked with all other gas appliances in the household running
on high. Failure to check this may result in lower than recommended required gas pressures,
resulting is poor performance and reduced flame effect.
NOTE
Rinnai
Remove
all
packaging
COMMISSIONING
C
A
B
27
RDV 600_700ER IM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdv700er

Table of Contents