Modbus Driver Settings - Siemens SITRANS F Operating Instructions Manual

Communication modules modbus rtu rs485
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Modbus holding registers
A.2 MODBUS driver settings
Table A- 2
Process data, MASS 6000
MODBUS
MODBUS
register
address
4:03001
3000
4:03003
3002
4:03005
3004
4:03007
3006
4:03009
3008
4:03011
3010
4:03013
3012
4:03015
3014
4:03019
3018
4:03023
3022
4:03025
3024
4:03100
3099
A.2

MODBUS driver settings

Table A- 3
MODBUS driver settings
MODBUS
MODBUS
register
address
4:00501
500
4:00502
501
4:00504
503
4:00505
504
4:00508
507
4:00512
511
4:00513
512
4:00514
513
4:00515
514
4:00529
528
38
No. of bytes Data type
4
Float
4
Float
4
Float
4
Float
4
Float
4
Float
4
Float
8
Double
8
Double
4
Float
4
Float
2
Byte
No. of bytes Data type
2
Word
2
Word
2
Word
2
Word
4
Dword
2
Word
2
Word
2
Word
4
Dword
2
Byte
Description
Absolute Massflow (kg/s)
Absolute Volumeflow (m3/s)
Absolute Density (kg/m3)
Sensor temperature (°C)
Fraction A (kg/s)
Fraction B (kg/s)
% fraction A (%)
Totalizer 1 (kg or m3)
Totalizer 2/Batch (kg or m3)
Totalizer 1 (kg or m3)
Totalizer 2/Batch (kg or m
Update rate set:
1. Reserved
2. All process data updated with 2 Hz
3. Like set 1, but with Massflow 10 Hz
4. Like set 2, but with Totalizers 5 Hz
5. Like set 1, but with Massflow 30 Hz
Description
No. of ParityErrors
No. of FramingErrors
No. of CRC Errors
No. of Ok Messages (received)
InterFrameSpace (us)
Response Timeout (ms)
Response Delay (ms)
10xInterFrameSpace (10 x chars)
Baudrate as double word
Device address (1 - 247)
Operating Instructions, 06/2010, A5E00753974-04
Read / write
R
R
R
R
R
R
R
R
R
R
)
R
3
R/W
Read / write
R
R
R
R
R
R/W
R/W
R/W
R
R/W
Modbus RTU RS485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents