Quick Reference Guide
Page 19
Solution 6+6
Figure 7: Wiring Diagram For Two Area Addressable Codepads
The following DIP switch settings and locations must be programmed for the two "Area Addressable" codepads
to operate correctly.
Area 1 Codepad
DIP Switch 1 on the back of the remote codepad will need to be in the "ON" position. The following location
will also need to be programmed.
[LOCATION 228, Option Bit 1 must be enabled]
Area 2 Codepad - (Output 1)
DIP Switch 2 on the back of the remote codepad will need to be in the "ON" position. The following locations
for Output 1 will also need to be programmed.
[LOCATION 186 = 6, LOCATION 187 = 1]
Bosch Security Systems Pty Limited
SOL 6+6 QUICK REF GUIDE.DOC