Nortel CallPilot 702t Installation And Configuration Manual page 238

Maintenance and diagnostics
Hide thumbs Also See for CallPilot 702t:
Table of Contents

Advertisement

Performing RAID maintenance
9 Repeat steps 6 to 8 for drives B-1 and C-1.
10 Before continuing, verify that drives A-0, B-0, and C-0 are dead (DED),
and drives A-1, B1, and C-1 are online (ONL), as in the following
example:
11 Press Esc to return to the main menu.
12 Press Esc again to exit the utility.
Result: A prompt appears in the bottom right corner of the screen asking
you to confirm that you want to exit.
13 Disregard the reminder to save the configuration. Select YES, and then
press Enter to exit from the RAID configuration software without saving
the configuration.
14 Remove the CallPilot 2.0 OS Recovery CD-ROM or the CallPilot 2.0 OS
Upgrade CD-ROM.
15 Restart the CallPilot server.
16 Rebuild the DED hard drives by following steps 4 to 10 on page 229.
Result: These steps resynchronize the dead drives with the online pre-
upgrade drives. The CallPilot server is restored to its pre-upgrade state.