Performing RAID maintenance
d. Power up the server.
Result: POST messages from the RAID controller warn you that the
system is operating in critical mode (that is, with some drives offline).
2 Log on to the CallPilot server as Administrator (or any other user ID that
has administrative privileges).
3 From the Windows desktop, select Start
Workstation Array Manager.
Result: The Workstation Array Manager window appears. In the
example below, the secondary hard drive in logical drive 2 (channel 1, ID
5) was faulty and has been replaced. The new hard drive is offline, and
logical drive 2 is still in critical state because the new hard drive has not
yet been rebuilt.
4 In the Workstation Array Manager window, double-click the offline hard
drive (in the example in this procedure, this is the device at channel 1 ID
5).
Result: The Disk Device Information window appears.