Nortel CallPilot 1001rp Installation And Configuration Manual page 299

Maintenance and diagnostics
Hide thumbs Also See for CallPilot 1001rp:
Table of Contents

Advertisement

October 2002
DIP switch block on the Pentium II SBC
The following picture shows the location of the DIP switch block. The
switch settings shown are defaults. Do not change them.
To replace the SBC card
1 Power down the server.
2 Disconnect the power cord.
3 Remove the top cover.
4 Free and label all connectors from the SBC card.
5 Loosen and remove the screw located at the top of the I/O bracket.
6 Remove the I/O bracket.
7 Loosen and remove the screw located at the top of the card's faceplate.
8 Loosen the SBC and pull it up from the backplane.
9 Remove the new card from its protective wrapping.
Part 5: 1001rp Server Maintenance and Diagnostics
Maintaining the Pentium II SBC card
DIP switch block
(These are the
default settings; do
not change them.)
299