Creating A Ppar Configuration List - Fujitsu SPARC M12-1 Installation Manual

Hide thumbs Also See for SPARC M12-1:
Table of Contents

Advertisement

XSCF> showfru -a
Device
sb
cpu
Execute the setupfru command to set memory mirror mode to configure
2.
memory mirroring.
XSCF> setupfru [[-q] -{y|n}] - c function=mode device location
To configure memory mirroring, specify -c mirror=yes.
For "device," specify the devices making up the mirroring configuration. To
configure memory mirroring for the CPU mounted in the SPARC M12-1, specify
sb. To configure it only for the specified CPU, specify cpu.
For "location," specify the location of the target device.
When specifying sb for "device," specify 00-0 for "location." When specifying cpu
for "device," specify the location in the 00-0-z format. For z, specify 0.
The following example sets all the CPUs mounted in the SPARC M12-1 to
memory mirror mode.
XSCF> setupfru -c mirror=yes sb 00-0
 
Notice:
- Logical domain config_name will be set to "factory-default".
 
Memory mirror mode setting will be changed, Continue? [y|n] : y
Execute the showfru command to check the set memory mirror mode.
3.
XSCF> showfru -a
Device
sb
cpu
6.7

Creating a PPAR Configuration List

The SPARC M12-1 has only one physical partition. Therefore, a PPAR configuration
list is set for every SPARC M12-1. For the SPARC M12-1, you can set only the
98
Fujitsu SPARC M12-1 Installation Guide ・ June 2021
Location
Memory Mirror Mode
00-0
00-0-0
no
 
 
 
Location
Memory Mirror Mode
00-0
00-0-0
yes