Illustration
Blank -: Light OFF
Light
Power Temp Lamp
Power events
O
O
G
G
O
O
Lamp events
O
-
56
Maintenance
: Light flashing
: Light ON
Status & Description
The projector has just been connected to a power outlet.
O
O
-
-
Stand-by mode.
-
-
Powering up.
-
-
Normal operation.
1.
-
-
2.
The projector has shutdown automatically. If you try to re-start
-
-
the projector, it will shutdown again. Please contact your dealer
for assistance.
The projector has shutdown automatically. If you try to re-start
-
the projector, it will shutdown again. Please contact your dealer
R
for assistance.
1.
-
R
2.
O
: Orange light
R: Red light
G: Green light
The projector needs 90 seconds to cool down as it was
abnormally shut down without the normal cooling down
process. Or
The projector needs to cool for 90 seconds after the
power is turned off.
The projector needs 90 seconds to cool down. Or
Please contact your dealer for assistance.