11/2012
Relay contacts
relay mode
TCS TürControlSysteme AG, www.tcsag.de
TCS Hotline • Mail: hotline@tcsag.de
1 = switching relay closes for the determined period of time when activated
2 = camera relay closes when the call number is dialed and opens if the
communication is over (for external illumination).
3 = staircase light relay closes when dialing the call number and stays closed for
the determined period of time after the communication is over.
4 = bell relay closes after the call button was pressed and opens after the
determined period of time (for external bell).
5 = cascade connection, this mode is only for relay 2, if the relay was programmed
in mode 1.
Function: Relay 1 is activated for the determined period of time. The determined
delay time passes by, then the relay 2 is activated for the determined period of
time.
Note: This process is only started in case relay 1 is activated. Regardless of this, relay 2 can
be activated with the code.
19
Subject to technical changes.
PI_AVU940x0-uk