Fault Finding - Stanley BRANDON Operation Instructions Manual

Hide thumbs Also See for BRANDON:
Table of Contents

Advertisement

PROBLEM
1.
Poor Flue Draught:
2.
Excessive Flue Draught (a) High chimney.
3.
Down Draught:
4.
Cooker Smoking:
5.
Hot Plate Not Heating:
6.
Oven Not Heating:
DHW Model Only
It is of the utmost importance to keep the flue pipe and chimney clear of deposits. Blocked or partially obstructed
flueways and chimneys may cause dangerous fumes to be emitted into the room, these may well be invisible.
7.
If the user detects a problem where the appliance will not function, there are two checks which can be
carried out before calling your Local Service Agent.
1.
Check to see if the burner control box lock out reset button is illuminated,
burner to fire.
2.
The user can also check the high limit reset button, follow procedure as outlined on page 5, if this fails
to reset the appliance call your Local Service Agent.
Waterford Stanley Ltd.,
Bilberry, Waterford, Ireland.
T elephone:
Facsimile:
FAULT FINDINGS
CAUSE
(a) Obstruction.
(b) Chimney too low.
(c) Chimney not lined.
(d) Insufficient air supply.
(a) High trees
(b) High buildings
(c) Low chimney.
(d) Positive pressure zone.
(a) Insufficient primary air.
(b) Flue blocked or partially
blocked
(c) Downdraught.
(d) Poor combustion.
(a) Burner cutting out.
(b) Utensils not flat.
(a) Flueways blocked or partially
blocked.
(b) Dirty flueways.
(c) Insufficient gas supply.
(d) Burner not set correctly.
(e)
Cylinder thermostat interruption.
If problem persists call you Local Service Agent.
(051)
302300
(051)
302375
REMEDY
(a) Clear and clean.
(b) Raise height above ridge.
(c) Fit flue liner 125mm (5")
(d) Increase provision of free air for ventilation &
combustion.
(a) Fit draught stabiliser (External)
(a) Raise chimney height.
(b) Raise chimney height.
(c) Raise chimney height.
(d) Fit anti-down draught cowl.
(a) Provide additional room air inlet or adjust burner
air intake.
(b) Clean flue.
(c) Raise chimney height or fit anti-downdraught cowl.
(d) Check air supply, check gas rate, and burner
settings.
(a) Increase cooker thermostat setting.
(b) Use machined based utensils.
(a) Clean out.
(b) Clean flueways.
(c) Check gas rate.
(d) Commission burner correctly.
(e) Release hot water from cylinder.
16
If so, press it and wait for
Rev:001 DP 050729
N00354AXX

Hide quick links:

Advertisement

Table of Contents
loading