Fault Finding - Stanley Tara Mk3 Installation And Operation Instructions Manual

Oil stove
Table of Contents

Advertisement

If the stove exhibits any of the following conditions, call your commissioning engineer.
SYMPTOM
Stove will not light
Excessive flame noise
Dirty or Unstable flame
Door glass sooting up excessively

FAULT FINDING

POSSIBLE CAUSES
No electrical supply to the
stove
No Oil in tank
Manual or fire valves off
Control valve trigger down (off)
Thermal fuse in transformer blown
Oil feed line filter blocked
Fuel line air locked
Incorrect chimney draught
Incorrect fuel input rate
Incorrect flue draught
Incorrect fuel input rate
Down draughting
Incorrect fuel bed set-up
Incorrect flue draught
Poor door seal
Fuel input rate too high
19
REMEDY
Check Plug Top Fuse or connec-
tor block fuse.
Fill Tank
Open or reset valves.
Check for cause of over
temperature if necessary.
Reset trigger.
Replace transformer.
Free oil filter
Bleed fuel line
Check joint seals, increase
height of chimney adjust
draught regulator
Check fuel input rates,
adjust if necessary
Check joint seals, increase
height of chimney, adjust
draught regulator
Check fuel input rates,
adjust if necessary
Fit suitable cowl
Adjust coal positions
Check joint seals, increase
height of chimney, adjust
draught regulator
Replace door seal
Check fuel input rates,
adjust if necessary

Advertisement

Table of Contents
loading

Table of Contents