Genie Z-51/30J Service And Repair Manual page 82

Table of Contents

Advertisement

Service and Repair Manual
Control System Fault Codes
Error Source
ID
Name
46
Primary Extend/
Retract Switch
51
Drive Joystick
53
Drive Flow
Valve (EDC)
54
Drive Brake
Valve
72
Error Type
ID
Name
21
Fault
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
12
Value too high
15
Value too low
17
Not calibrated
21
Fault
Condition
Platform Ext/Ret frozen at neutral
Limited speed and direction.
Frozen at zero and neutral. Alarm
sounds indicating a fault
Limited speed and direction.
Frozen at zero and neutral. ALarm
sounds indicating a fault.
Normal function except threshold
for one or both directions is zero.
Drive frozen at zero and neutral.
Alarm sounds indicating a fault.
Z®-51/31J
October 2020
Solution
Power up controller with
problem corrected
Cycle power off, then on
after problem has been
corrected.
Cycle power off, then on
after problem has been
corrected.
Calibrate valve threshold.
Cycle power off, then on
after problem has been
corrected.