Dc Power Supply Specifications - Avaya Virtual Services Platform 8200 Installation Job Aid

Hide thumbs Also See for Virtual Services Platform 8200:
Table of Contents

Advertisement

Color and Status
Green (steady)
Green (blinking)
Amber (steady)
Amber (blinking)
Important:
You can hot swap power supplies while the switch is operational. One power supply is
required for continued switch operation.

DC power supply specifications

The VSP 8284XSQ-DC comes with one 800 W DC power supply and you can install a secondary
power supply for redundancy.
Important:
You must have either a power supply or a power supply cover in each bay to ensure proper
ventilation. Leaving a power supply bay unpopulated or uncovered impairs the ability of the fans
to cool the chassis.
Figure 3: DC power supply
The 800 W DC power supply uses a dongle to connect the power supply to the DC power source.
The following table describes the regulatory DC power specifications for the VSP 8284XSQ-DC
switch. Note that regulatory power specifications are based on the maximum rated capacity of the
power supplies and are not based on typical power consumption, which is typically lower.
June 2015
Description
There is output and the power supply is
operating normally.
The power supply is present, but its output is
standby voltage (12VSB).
SHUTDOWN: The power supply is not supplying
power to the switch because the power cord is
unplugged or the power supply shutdown for
faults such as a fan failure or exceeding limits for
Over Current Protection (OCP) or Over Voltage
Protection (OVP).
WARNING: The power supply continues to
operate, but there are one or more warning
events such as high temp, high power, high
current, or a slow fan.
Installation Job Aid for Avaya Virtual Services Platform 8200
10

Advertisement

Table of Contents
loading

Table of Contents