Ac Power Cord Specifications - Avaya Virtual Services Platform 8200 Installation Job Aid

Hide thumbs Also See for Virtual Services Platform 8200:
Table of Contents

Advertisement

The 800 W AC power supply uses an IEC 60320 C16 AC power cord connector. The AC power cord
is in close proximity to the hot air exhaust, and supports high operating temperatures.
Figure 2: IEC 60320 C16 connector
The following table describes the regulatory AC power specifications for the VSP 8284XSQ switch.
Note that regulatory power specifications are based on the maximum rated capacity of the power
supplies and are not based on typical power consumption, which is typically lower.
Table 4: AC power specifications
Input Current:
Input Voltage (rms):
Power Consumption:
Thermal Rating:
Inrush Current:
Turn on Condition:
Important:
12 V output rise time, from 10 to 90 percent, must be the maximum of 50 ms and monotonic under all
defined input and output conditions.
Efficiency:

AC power cord specifications

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 5: International power cord specifications
Country and Plug Specification
Continental Europe:
• CEE7 standard VII male plug
• Harmonized cord (HAR marking on the outside of the cord
jacket to comply with the CENELEC Harmonized
Document HD-21)
June 2015
8284XSQ-AC
15A/7.5A
100 to 240 VAC at 50 to 60 Hz
800 W maximum
2730 BTU/Hr maximum
40 A maximum
1 second maximum after application of AC power
70 percent minimum
Specifications
• 220 or 230VAC
• 50 Hz
• Single phase
Installation Job Aid for Avaya Virtual Services Platform 8200
Typical Plug
Table continues...