Avaya Virtual Services Platform 8200 Installation Job Aid page 8

Hide thumbs Also See for Virtual Services Platform 8200:
Table of Contents

Advertisement

Procedure
1. Remove the two screws that secure the filler panel to the chassis. (Save the filler panel for
possible future use.)
2. Slide the power supply into the slot.
3. Verify that the power supply is fully seated in the slot. The spring latch should engage and
return to its original position.
Note:
The chassis design prevents an incorrect installation of a power supply. If you insert a
power supply upside down, it will not fully insert.
Important:
The VSP 8200 does not have a power switch. When you connect the DC power source
to the dongle and then plug the dongle into the DC power supply, the switch powers up
immediately.
Warning:
Disconnecting the DC dongle from the power supply is the only way to turn off DC power
to the VSP 8200. Allow at least 30 seconds for the VSP 8200 to fully power down before
restoring power. Otherwise, the VSP 8200 might produce a core file during the reset
leading to an extra delay during boot time.
4. Once you install a power supply, use the following steps to connect the dongle:
a. Avaya supplies a universal dongle to connect the DC power supply to the DC input
power source. However, Avaya does not supply the cables for connecting the DC power
supply to the DC input power source. Select cables that comply with the electrical code
June 2015