10-1. Installation Diagram of Indoor and Outdoor Units
Air f lter
6
Filter
5
Filter
3
Batteries
2
Wireless remote control
7
Mounting screw
CAUTION
Install in rooms that are 13 m³ or larger.
If a leak of refrigerator gas occurs
inside the room, an oxygen def ciency
can occur.
• Loading Batteries
1.
Remove the battery cover.
2.
Insert 2 new batteries (AAA type)
following the (+) and (–) positions.

10. INSTALLATION PROCEDURE

1
50 mm or more
8
Flat head
wood screw
9
Insulation sheet
Before installing the wireless remote controller
2 Wireless remote controller
Installation plate
50 mm or more
Shield pipe
4
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available, provided
by installer)
- 69 -
Do not allow the drain hose to get
slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Rear left
Bottom right
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam
In case of right or left piping
Cut dot-line area
3 Batteries
Left