Item
Operation flow and applicable data,etc
As shown in the table, the max. revolution number of
30. Outdoor
compressor can be reduced.
Quiet
As the max. number of revolution of compressor is restricted.
control
the rise-up performance at the start time is weakened.
(for only
This function is disable with multi-outdoor unit connecting.
1:1 outdoor
MODE
unit)
Cooling
Heating
* Refer to CDU service manual combined).
When air conditioner is on standby before setting.
< How to set Outdoor Quiet control >
1. Push and hold OPERATION button for 20seconds.
2. After holding 20seconds, beep sounds is heard and
OPERATION indicator flashes for 5seconds.
Release OPERATION button.
3. Push OPERATION button to stop temporary operation.
(Set Auto restart function again)
< How to cancel Outdoor Quiet control >
1. Push and hold OPERATION button for 20seconds.
2. After holding 20seconds, beep sounds is heard.
(OPERATION indicator doesn't flash).
Release OPERATION button.
3. Push OPERATION button to stop temporary operation.
(Set Auto restart function again)
B10J2FVG-E
B13J2FVG-E
Normal
Normal
(rps)
(rps)
61
82
85
94
OPERATION button
OPERATION indicator
OPERATION button
- 55 -
1. Purpose
For the users who concern about
noise of the outdoor unit, this control
controls the max. revolution number
of the compressor to reduce the
noise.
B18J2FVG-E
Normal
2. Description
(rps)
80
• It can be change setting whether air
83
conditioner is operationg or not.
• After pushing OPERATION button, air
conditioner starts operation.
• After 3seconds, 3 beeps are heard.
(Auto restart setting is changed.)
• After 10seconds, a beep is heard.
(Temporary operation starts and Auto
restart function is cancelled.)
• After pushing OPERATION button, air
conditioner starts operation.
• After 3seconds, 3 beeps are heard.
(Auto restart setting is changed.)
• After 10seconds, a beep is heard.
(Temporary operation starts and Auto
restart function is cancelled.)
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents