Operation Description 1. Basic Operation; Operation Control - Toshiba RAS-B10J2FVG-E Service Manual

Air conditioner split type
Hide thumbs Also See for RAS-B10J2FVG-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
1. Basic

1. Operation control

operation
Receiving the user's operation condition setup, the operation statuses of indoor/outdoor units are
controlled.
1) The operation conditions are selected by the remote controller or indoor unit display buttons as
shown in the bolow.
2) A signal is sent by ON button of the remote controller.
3) The signal is received by a sensor of the indoor unit and processed by the indoor controllers as
shown in the below.
4) The indoor controller controls the indoor fan motor and louver motor.
5) The indoor controller sends the operation command to the outdoor controller, and sends/receives
the control status with a serial signal.
6) The outdoor controller controls the operation as shown in the left, and also controls the compres-
sor, outdoor fan motor, 4-way valve and pulse Modulating valve.
Selection of
operation conditions
ON/OFF
Signal receiving
Indoor unit control
Operation command
Serial signal send/receive
Serial signal send/receive
Outdoor unit control
Remote controller
Control contents of remote controller
• ON/OFF
• Operation select (AUTO/COOL/DRY/HEAT/FAN ONLY)
• Temperature setup
• Air direction
• Swing
• Air volume select
(AUTO/LOW/LOW+/MED/MED+/HIGH/QUIET)
COMFORT SLEEP
ECO
POWER-SEL
ON timer setup
PRESET
OFF timer setup
SILENT
Hi-POWER
Fireplace
FLOOR
8°C
WEEKLY TIMER
Indoor unit
Indoor unit control
• Command signal generating function of
indoor unit operation
• Calculation function (temperature calculation)
• Activation compensation function of indoor fan
• Cold draft preventive function
• Timer function
• Indoor heat exchanger release control
Outdoor unit
Outdoor unit control
• Frequency control of inverter output
• Waveform composite function
• Calculation function
(Temperature calculation)
• AD conversion function
• Quick heating function
• Delay function of compressor reactivation
• Current release function
• IPM over-current preventive function
• Defrost operation function
Selecton
of
operation
conditions
Inverter
- 31 -
Description
Indoor unit display buttons
Control contents of
unit display buttons
• ON/OFF
• Operation select
(AUTO/COOL/HEAT/
FAN ONLY)
• Temperature setup
• Air outlet select
(AUTO/Upper/Lower
• Indoor fan motor
• Louver motor
~
• Compressor
• Outdoor fan motor
• 4-way valve
• Pulse Modulating valve
(P.M.V.)