Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
TA-Tsc
[ °C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
(table 1) Indoor fan air flow rate <Cooling>
Fan speed
RAS-B10J2FVG-E
level
Cool
Fan speed
(rpm)
WF
UH
530
WE
H
530
WD
M+
530
WC
480
WB
M
450
400
WA
W9
L+
360
W8
L
350
W7
L−
300
W6
260
UL
W5
260
W4
240
W3
240
W2
SUL
240
W1
240
Operation flow and applicable data, etc.
MANUAL
Indication
Fan speed
L
L+
(L + M) / 2
M
M+
(M + H) / 2
H
*3 : Fan speed = (M + −L) x 3/4 + L
Fan speed
Hi Power
*4 : Fan speed = (M + −L) x 2/4 + L
M+(WC)
H+(WD)
*5 : Fan speed = (M + −L) x 1/4 + L
*3
*6
(Linear appro ximation
from M+ and L)
*7
*4
*6 : Fan speed = (H −L+) x 3/4 + L+
*5
*8
*7 : Fan speed = (H −L+) x 2/4 + L+
L(W7)
L+(W8)
*8 : Fan speed = (H −L+) x 1/4 + L+
(Linear appro ximation
from H and L+)
RAS-B13J2FVG-E
Air flow rate
Fan speed
(m3/h)
(rpm)
498
560
498
560
498
550
447
500
414
490
366
440
324
390
315
390
258
340
216
270
216
270
198
250
198
240
198
240
198
240
(Fig. 1)
Hi-POWER
W7
W8
(L + M) / 2
WA
WC
(M + H) / 2
WD
WE
(Fig. 2)
RAS-B18J2FVG-E
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
528
650
624
528
650
624
519
630
600
468
560
528
459
560
528
408
500
468
354
450
414
354
450
414
300
400
366
228
360
324
228
340
300
210
320
282
198
300
258
198
300
258
198
300
258
- 34 -
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.