Dry Operation - Toshiba RAS-B10J2FVG-E Service Manual

Air conditioner split type
Hide thumbs Also See for RAS-B10J2FVG-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data, etc.
1. Basic

4. DRY operation

operation
DRY operation is performed according to the
difference between room temperature and the setup
temperature as shown below.
In DRY operation, fan speed is controlled in order to
prevent lowering of the room temperature.
TA
(°C)
+4.5
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
−0.5
−1.0
−1.5
−2.0
Zone
Compressor speed (rps)
B10J2FVG-E B13J2FVG-E B18J2FVG-E
12
35
37
11
32
34
10
30
31
9
27
28
8
25
26
7
22
23
6
20
20
5
4
3
2
1
OFF
OFF
0
- 33 -
Description
1) Detects the room temperature (TA) when
the DRY operation started.
2) Starts operation under conditions in the
left figure according to the temperature
difference between the room tempera-
ture and the setup temperature (Tsc).
Setup temperature (Tsc)
= Set temperature on remote controller
(Ts) + (-1.0 to 0.0)
3) When the room temperature is lower
2°C or less than the setup temperature,
turn off the compressor.
4) The time correction is performed every
8 minutes.
Fan
speed
49
W8
42
W6
36
30
24
18
11
W5
W4
OFF
Time
correction
+1 zone
±0
−1 zone
(min 1)