6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
Part s n ame
No.
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
5
Louver motor
6
Dumper motor
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way valve coil
5
Reactor
6
Suction temp. sensor
7
Discharge temp. sensor
8
Outside air temp. sensor
9
Heat Exchanger temp. sensor
10
Terminal block
Parts name
RAS-10
RAS-13
RAS-18
RAS-10, 18
RAS-13
RAS-18
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
(5 poles)
Type
ICF-340-41-1
DC340, 41W
( - )
10k
(
)
10kΩ at 25°C
-
(
)
10kΩ at 25°C
-
MP24Z3N
Output (Rated), 16 poles, DC12V
MP24Z3N
Output (Rated), 16 poles, DC12V
Type name
KSK75D43UEZA
KSK89D53UFZ
KTN130D30UFZ
WDF-340-A43-1
PQ-M10012-000313
SQ-A2522G-000352
DXQ-939
CH-69-Z-T
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-5B
- 21 -
Specif icat io ns
at 25°C
Specifications
3-Phases (6-Poles) ;
3-Phases (6-Poles) ;
3-Phases (6-Poles) ; 1075W
DC 140-340V ; 43W
DC 12V
AC 220-240V
AC 220-240V
L = 19mH, 10A
10kΩ at 25°C
62kΩ at 20°C
10kΩ at 25°C
10kΩ at 25°C
AC 250V, 20A
610W
715W