Item
Operation flow and applicable data,etc
<With Quiet control/Non-select method>
22. Outdoor
Quiet
control
Select "Control" or "No control" by keeping
[RESET] button pushed for 20 seconds.
("No control" at shipment from the factory.)
Exchanging from "No control" to "Control" :
Beep sound is heard (Pi, Pi, Pi, Pi, Pi) and
the operation LED 5Hz flashes for 5
seconds.
Exchanging from "Control" to "No control" :
Beep sound is heard.
(Operation LED does not flash.)
<Maximum number of revolution of compressor at normal time and Quiet control time>
Outside temp.
(TO)
COOL
−5°C ~
HEAT
−10 ~ −5°C ~
−10°C ~
* Refer to the service manual of outdoor unit which combined.
23. Operation
* Refer to the service manual of outdoor unit
mode
which combined.
selectable
24. Fireplace
Fireplace button on remote controller is pressed.
Operation
Fireplace 1:
Cancel cold draft prevention control and fan
speed depend on user require base on basic
control.
Fireplace 2:
Cold draft prevention control is active with super
low fan speed (640 rpm).

Fireplace Operation

RAS-M10PKVPG-E
Normal time
Quiet controlled
(rps)
(rps)
*
*
*
*
*
*
*
*
Fireplace#1
Fireplace#2
Normal
operation
1. Purpose
For the users who concern about noise
of the outdoor unit, this control controls
the max. revolutions of the compressor
to reduce the noise.
2. Description
To reduce noise, [RESET] button of the
indoor unit is kept pushed for 20
seconds.
The number of revolution for the indoor
fan motor and the seup temp value are
kept as they are.
3. Operation
As shown in the table, the maximum
revolution number of indoor unit
compressor can be reduced.
As the maximum number of revolution
of the compressor is restricted, the rise-
up performance at the start time is
weakened.
RAS-M13PKVPG-E
Normal time
Quiet controlled
(rps)
(rps)
*
*
*
*
*
*
*
*
Keep air circulation during other heat
source applied.
Note:
With Fireplace operation on heating
mode indoor unit always runs and cold
air breezing might be occurred.
8°C
- 43 -
FILE NO. SVM-18047
Description
RAS-M16PKVPG-E
Normal time
Quiet controlled
(rps)
(rps)
*
*
*
*
*
*
*
*