Setting a Time Program
32
You can set these heating times by adjusting the time
program for the heating water buffer tank. During the set
time phases, the charging condition of the heating water
buffer tank has an effect on the boiler operation.
Note: If you are using a solar thermal system for central
heating backup, balance the charging times of the
heating water buffer tank with the control unit of
the solar thermal system.
The time program for the heating water buffer tank is
made up of time phases. A time phase from 6:00 am
to 10:00 pm (06:00 to 22:00 h) every day is set at
the factory.
The time program for the heating water buffer tank
is preset to Automatic mode at the factory.
In automatic mode, the time program for the heating
water buffer tank is disregarded.
If you don't require automatic mode, you can select
up to 4 individual time phases per day. For each time
phase you set the start and end points.
In the "Extended menu", you can call up the current
time program under "Information" (see page 40).
Settings in the extended menu:
1.
for "Extended menu".
2.
/
for "Buffer"
|
~
3. d to confirm.
4.
/
for "Time program"
|
~
5. d to confirm.
6.
/
for "Individual"
|
~
7. d to confirm.
8.
/
to select the required part of the week or day.
|
~
9. d to confirm.
10.
/
for selecting the time phase !, ?, § or $.
|
~
11. d to confirm.
12.
/
to set the start point.
|
~
13. d to confirm.
14.
/
to set the end point.
|
~
15. d to confirm.
Example shown:
Time program for Monday to Friday ("Mo-Fr")
Time phase !: from 4:30 am to 8:30 am
(04:30 to 08:30 h)
Time phase ?: from 4:30 pm to 11:00 pm
(16:30 to 23:00 h)
Deleting time phases
To delete a time phase, press the following keys:
1. Proceed as described in points 1 to 12 of chapter
"Setting a time program".
2. d until the end point of the selected time phase
is displayed.
3.
/
until "- - : - -" is displayed for the end point.
|
~
4. d to confirm.
5.
until the default display is shown.