Shutting Down The Heating System For An Extended Period; Shutdown - Viessmann VITOLIGNO 300-C Operating Instructions Manual

Wood pellet boiler, with ecotronic weather compensated, digital boiler and heating circuit control unit, heating input: 44 mbh to 193 mbh, 13 kw to 57 kw
Table of Contents

Advertisement

Vitoligno 300-C Operating
Scanning Information
Calling up temperatures
You can scan temperatures in the standard menu and
in the extended menu. The range of displayed values
is wider in the extended menu. We therefore recommend
calling up temperatures via the extended menu.
Calling up temperatures in the standard menu
Press the following keys:
1.
/
for "Information"
|
~
2. d to confirm.
3.
/
for "Outdoor temperature", "Heating" or "DHW".
|
~
The overview below shows the temperatures displayed in
the "Heating" and "DHW" submenus.
"Heating" sub-menu:
Set supply temperature
Actual supply temperature
"DHW" sub-menu:
Set DHW temperature
Actual DHW temperature
Set return temperature
Actual return temperature
Scanning the heating water buffer tank temperatures
in the standard menu
Press the following keys:
1.
/
for "Buffer"
|
~
2. d to confirm.
3.
/
to display the required temperature
|
~
The following temperatures can be called up in the
"Buffer" menu:
Set buffer
Buffer average
Buffer sensors

Shutting Down the Heating System for an Extended Period

Shutdown

1. Switch off the boiler by pressing "START/STOP"
on the control unit.
2. Wait until the run-on time has passed and let the
boiler cool down.
(continued)
Calling up temperatures in the extended menu
Press the following keys:
1.
for "Extended menu".
2.
/
for "Information"
|
~
3. d to confirm.
4.
/
for "General", "Boiler", "Heating" or "DHW".
|
~
The following overviews show the temperatures
displayed in the sub-menus.
5. d to confirm.
Temperatures in "General" sub-menu:
Outdoor temperature
Set system temperature
Temperatures in "Boiler" sub-menu:
Boiler water temperature
Boiler return
Flue gas temperature
Temperatures in "Heating" sub-menu:
Set room temperature
Set reduced room temperature
Set supply temperature
Actual supply temperature
Temperature in "DHW" sub-menu:
Set DHW temperature
Actual DHW temperature
Set return temperature
Actual return temperature
You can switch your heating system off if you do not intend
to use it. We recommend you contact your heating contractor
before and after shutting down for longer periods.
Your heating contractor can then take suitable steps,
such as frost protection for the system or heating surface
preservation, as required.
Note: No special measures are required when shutting
down the system on a temporary basis.
3. Perform all work described in the overview of chapter
"Maintenance" starting on page 44.
4. When there is a risk of frost, drain the boiler,
observing the instructions issued by your heating
system installer or ask them to charge the system
with antifreeze.
Scanning
41