3-1. Overview of Error Message
Error messages are described on Section 3-2 in the order of list.
Error List
Code
Message
on time data display area
_
NO COMMUNICATION
01
REEL TROUBLE
02
REEL TROUBLE
03
REEL TROUBLE
04
REEL TROUBLE
05
REEL TROUBLE
06
TAPE TENSION
07
CAPSTAN TROUBLE
08
DRUM TROUBLE
09
TH/UNTH MOTOR
0A
THREADING
10
HUMID
11
TAPE T/E SENSOR
12
TAPE TOP SENSOR
13
TAPE END SENSOR
14
FAN MOTOR
20
CASS COMP MOTOR
21
REEL SFT MOTOR
22
REEL POS SENSOR
23
THRED RING SENS
92
INTERNAL I/F 1
93
CPU INITIALIZE ERROR
95
OTHERS NV-RAM ERROR 3-17
96
SY NV-RAM ERROR
97
SV NV-RAM
98
RF NV-RAM ERROR
99
INTERNAL I/F 2
3-2
Page Description
3-4
Abnormality in the interface between the lower control panel (KY-438 board) and SYS1 CPU
(SS-83 board) is detected in the lower control panel side.
3-4
Tape slacking is detected in the threading or unthreading operation.
3-5
Tape slacking or tape breaking is detected in the SEARCH, FF, or REW mode.
3-6
Tape slacking, tape breaking, or supply or take-up reel locking is detected in the REC or PLAY
mode.
3-7
A malfunctional tape transport speed is detected in the FF or REW mode.
3-7
The malfunctional operation of the supply or take-up reel is detected during cassette insertion.
3-8
Excessive tape tension is detected in the REC or PLAY mode.
3-8
Malfunction of capstan motor is detected.
3-9
Malfunction of drum motor is detected.
3-9
Malfunction of threading or unthreading operation is detected.
3-10
It is detected that the tape top processing is not completed in the threading mode.
3-10
Dew condensation is detected.
3-11
The tape top and tape end are detected simultaneously.
3-11
Malfunction of tape top sensor is detected.
3-12
Malfunction of tape end sensor is detected.
3-13
Malfunction of cooling fan motor is detected.
3-14
Malfunction of cassette compartment-up or down operation is detected.
3-14
Malfunction of movement of the reel table corresponding to the cassette size is detected.
3-15
The L-cassette and S-cassette positions of the reel table are detected simultaneously.
3-15
The thread end and unthread end states of the threading ring are detected simultaneously.
3-16
Abnormality in the interface between SYS1 CPU (on SS-83 board) and other CPU/MPU is
detected.
3-17
Abnormality in the interface between SV CPU (on SS-83 board) and DT MPU (on SS-83
board) or DRUM MPU (on SS-83 board) is detected.
Abnormality operation of an NV-RAM on RM-179/190 board is detected.
3-18
The abnormal operation of an NV-RAM (on SS-83 board) for the system control system is
detected.
3-19
The abnormal operation of an NV-RAM (on MS-58 board) for the servo system is detected.
3-19
The abnormal operation of an NV-RAM (on EQ-75, DM-89, or TBC-23A board) for the RF
system is detected.
3-20
Abnormality in the interface between SYS2 CPU (on SS-83 board) and SERVO CPU (on SS-
83 board) or MPU (on EQ-75, DM-89, TBC-23A, or SDI-41 board) or FL (level meter module)
is detected.