4-4. OTHERS CHECK Mode (M3)

4-4-7. METER HEAD ROOM Setup Menu (M37)

4-4-8. 50PIN DATA ASSIGN Mode (M39)

4-4-7. METER HEAD ROOM Setup Menu
(M37)
This menu can change the head room setting of an audio
level meter.
The head room can be selected from among the followings.
(The factory setting is 20 dB.)
20 dB, 18 dB, 16 dB, 15 dB, 14 dB, 12 dB, 9 dB
M3:OTHERS
M37:METER HEAD ROOM
*
20dB
Push SET button
Head room setting
(1) Turn the search dial while pressing the JOG button,
and the desired setting is then displayed.
. On changing the setting, a message "Push SET
Button" will be displayed on only the superimposed
display.
. To cancel the setting, press the MENU button to
terminate this menu.
(2) Press the SET button to save the changed setting.
. On pressing, a message "Saving..." will be displayed
on only the superimposed display. If no abnormality
is found, the display changes to "Save Complete"
after a few seconds.
To turn off "Save Complete", turn the search dial.
4-88
4-4-8. 50PIN DATA ASSIGN Mode (M39)
The M39 : 50PIN DATA ASSIGN changes and resets the
pin setup data of 50-pin parallel remote which are settable.
Also displays the logic level of the input pin.
Three menus are available.
M39 : 50 PIN DATA ASSIGN
M390 : INPUT PIN ASSIGN
M391 : OUTPUT PIN ASSIGN
M392 : NV-RAM CONTOROL
Menu Tree of 50PIN DATA ASSIGN
c
Do not change the setting data carelessly. This may cause a
trouble. For the actual setting, refer to the optional parallel
remote (50-pin) connector interface manual.
If you have changed the setting data carelessly, execute
ALL DATA PREVIOUS in M392 : NV-RAM CONTROL
menu or turn off the power of this unit without selecting
M392 : NV-RAM CONTROL. Never execute SAVE ALL
DATA.