AMX NetLinx NXP-TPI/4 Operation/Reference Manual page 104

Touch panel interface 4, firmware version g4
Hide thumbs Also See for NetLinx NXP-TPI/4:
Table of Contents

Advertisement

Programming
"^" Button Commands (Cont.)
^BOR
Set a border to a
specific border
style associated
with a border
value for those
buttons with a
defined address
range.
^BOS
Set the video
window slot ID #
to the new Slot
ID #.
^BPP
Set or clear the
protected page flip
flag of a
button.
98
Refer to theBorder Styles and Programming Numbers table on page 86 for more
information.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variable:
variable text address range = 1 - 4000.
border style name = Refer to theBorder Styles and Programming Numbers table on
page 86.
border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of
500-504 & 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
The border style is available through the TPDesign4 border-style drop-down list. Refer to
theTPD4 Border Styles by Name table on page 86 for more information.
The new Slot ID # is set only if the specified slot is not the same as the current slot
selected. Pass-thru sets the pass-thru mode to On.
This is an optional parameter and ONLY passes data to the PC.
Syntax:
"'^BOS-<vt addr range>,<button states range>,<slot number>,<pass-
thru>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
slot number = 0 = No Video Fill (Video Off)
1 - 4 = Video Fill (Video On)
pass-thru = Pass-thru disable = 0 or Pass-thru enable = 1.
Example:
SEND_COMMAND Panel,"'^BOS-500,1,1'"
Sets the button to display Composite video with no pass-thru.
Example:
SEND_COMMAND Panel,"'^BOS-500,1,2,1'"
Sets the button to display video in Slot 2 with pass-thru enabled.
Refer to theVideo Adjustment Slide-Out Option Bar section on page 62 for more informa-
tion on the slot assignments within a panel.
Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variable:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).