3: G4Cc (Computer Control) Configuration; Using Configcc.exe To Configure G4Cc - AMX MIO-R4 Operation/Reference Manual

Touch panel design program (v2.10 or higher)
Hide thumbs Also See for MIO-R4:
Table of Contents

Advertisement

Appendix A: G4 Computer Control
2. cc-GuestPC.tko is located in the module folder on the USB stick. The cc-GuestPC.tko file needs to
be added to your workspace in Studio to compile with source code.
3. Compile and load source code to NetLinx master.

3: G4CC (Computer Control) Configuration:

Launch configCC.exe (on the USB stick). Use this application to configure G4CC.

Using configCC.exe to Configure G4CC

configCC.exe is the Configuration Utility for G4CC (included on the same USB stick). Use this
application to designate up to four Modero / TPI/4 panels that will be allowed to control this computer.
1. Connect the computer to an Ethernet Network that can communicate with the NetLinx Control
System.
2. Insert the USB Computer Control Stick into the USB port on the computer that is being controlled.
A series of USB driver installation popup windows appear.
3. Confirm that a new USB detection icon appears in the lower-right taskbar of the display window.
4. Use the computer's file browser to navigate to the USB stick's drive location and open the Config
folder on the USB Control Stick drive directory.
5. Double-click the configCC executable to run the G4 Computer Control Configuration Utility from
the NXA-USBTN drive (FIG. 93).
FIG. 93
G4 Computer Control Configuration Utility (configCC.exe)
This application allows you to designate up to four Modero or TPI/4 panels with rights to
control this computer.
The following information is needed for each Modero or TPI/4 panel:
230
- local name for this instance of the cc-GuestPC module
< mdlGuestPC >
- device for cc-GuestPC to use for internal data events; this should be a
< vdvGuestPC >
DEFINE_DEVICE for the events to work properly
NetLinx Master IP Address/DNS (Fixed IP/URL)____.____.____.____
(Acquire the IP address of the NetLinx master by using NetLinx Studio 2.1 Diagnostics Tab /
Network Addresses / Get IP Information).
G4 Touch Panel Device ID: _______
(Acquire the panel device number in the online tree of NetLinx Studio).
G4 Touch Panel System: _______
(Acquire the system number in the online tree of NetLinx Studio).