Working With Properties
Programming Properties (Cont.)

Range High

Range Inverted

Range Low

Range Time Down

Range Time Up

String Output

String Output Port

Level Control Parameters

The Level Control Type options allow General and Multi-State General buttons to directly control a level
without the need for NetLinx code. Select a level control type for the selected button (Absolute, Relative
or None):
These options require the following additional parameters to be defined:
Level Control Parameters

Level Code

Level Control Repeat

Level Control Value

Level Port

Range High
Range Low
Range Time Down
Range Time Up
122
Set the top of the bargraph/joystick range (0-255).
Bargraph and Joystick buttons only.
Travel top to bottom or right to left (depending on the Direction setting, default =
Off).
Bargraph and Joystick buttons only.
Set the bottom of the bargraph/joystick range (0-255).
Bargraph and Joystick buttons only.
Specify the amount of time (in 1/10th seconds) it will take for the bargraph to go
from the top to the bottom of the specified range (default = 2). It is not applicable
if the Level Function property is set to "display only".
Specify the amount of time (in 1/10th seconds) it will take for the bargraph to go
from the bottom to the top of the specified range (default = 2). It is not applicable
if the Level Function property is set to "display only".
Specify the output string sent to the master on button push. Click the browse but-
ton (...) to open the Enter Text dialog. Enter the output string and click OK (or
Cancel to exit without saving).
Select or enter the port to which the output string will be applied.
Absolute: The button acts like a preset and sets the level to the desired value.
Relative: The button increments or decrements the current level value by a fixed amount.
Select or enter the level code sent to the master on the selected port. Select Auto-
Assign to automatically assign the level code to this button.
This value determines the repeat time (in 1/10th-second increments) for relative
level control.
For example, if this value is set to 10, the user can hold the button down for one
second to cause the level to raise or lower repeatedly (according to the specified
Level Control Value) without having to press the button each time.
Relative Level Control only.
For Absolute level control, this value determines the level value that will be recalled
by this button. For Relative level control, this value determines the amount of
adjustment relative to the current level resulting from this button. For relative level
control, this value can be entered as a positive integer (to raise the relative level
setting) or a negative integer (to lower the relative level setting).
Select or enter the port to which the Level code will be applied. Select 0 (Setup port)
or 1 as the level port for this button.
Set the top of the level range (0-255).
Set the bottom of the level range (0-255).
Set the time (in 1/10th-second increments) that it takes to ramp from the top to the
bottom of the specified range (default = 2).
Set the time (in 1/10th-second increments) that it takes to ramp from the bottom to
the top of the specified range (default = 2).
TPDesign4 Touch Panel Design Software (v2.10 or higher)