Hilti TE 3000-AVR Manual page 27

Hide thumbs Also See for TE 3000-AVR:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
Trouble or fault
The breaker doesn't start.
The service indicator lights
red.
Service indicator flashes red.
"Ready for operation" indica-
tor flashes green.
No hammering action.
The breaker doesn't start or
cuts out during operation.
10
Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
11
RoHS (Restriction of Hazardous Substances)
Click on the link to go to the table of hazardous substances: qr.hilti.com/r11668382.
There is a link to the RoHS table, in the form of a QR code, at the end of this document.
12
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
*2228667*
Possible cause
Generator in sleep mode
The detachable supply cord is not
plugged in correctly
The tool is faulty or servicing is due ▶ Have the product repaired only
Temporary fault
The voltage provided by the elec-
tric supply is too high.
Protection against overheating
The power tool is too cold
The extension cord is too long or
the conductor cross-section is
inadequate
2228667
Action to be taken
▶ Apply a load to the generator
by connecting a second power
consumer (e.g. worklight).
Switch the tool off and then on
again.
▶ Fit the detachable supply cord
to the power tool correctly.
by Hilti Service.
▶ i. Wait 10 seconds for the
flashing to stop.
▶ If the flashing does not stop
within 10 seconds, unplug the
supply cord from the power
supply and wait for 2 minutes.
▶ If the flashing does not stop,
bring the product to Hilti
Service.
▶ Use a different power outlet.
Check the electric supply.
▶ Allow the product to cool down.
▶ Clean the air vents. Running
under no load is still possible.
▶ Bring the tip of the accessory
tool into contact with the
working surface, switch the
power tool on and allow it to
run. If necessary, repeat the
procedure until the hammering
mechanism begins to operate.
▶ Use an extension cord of an
approved length and / or of
adequate conductor cross-
section.
English
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents