When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Weight in accordance with EPTA procedure 01
Single impact energy in accordance with the EPTA procedure
Storage temperature
Ambient temperature for operation
4.1
Noise information and vibration values in accordance with EN 60745
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure. The data given represents the main applications of the power tool.
However, if the power tool is used for different applications, with different accessory tools, or is poorly
maintained, the data can vary. This can significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: Maintaining the power tool and accessory tools, keeping the hands warm,
organization of work patterns.
Noise information
Sound power level (L
WA
Uncertainty for the sound power level (K
Sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration information
Chiseling (a
)
h, Cheq
Uncertainty (K)
4.2
Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
Check the extension cord for damage at regular intervals.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via a link,
in the form of a QR code, at the end of this document.
5
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
*2228667*
)
)
WA
)
pA
)
pA
2228667
TE 3000­AVR
27.1 kg
85 J
−20 ℃ ... 70 ℃
−20 ℃ ... 55 ℃
106 dB(A)
3 dB(A)
95 dB(A)
3 dB(A)
6.9 m/s²
1.5 m/s²
English