3.1.2. Performance flow rate characteristics

NOTE
Flow rates are indicative data. Maximum flow rate to produce in order to respect the required service
velocity for an optimal ion exchange upon resin manufacturers recommendation, regardless of the
inlet pressure.
Nominal (residual hardness 0°f) ......................0.32 m
Nominal (residual hardness 10°f, 30% mix.) ...0.42 m
Peak (residual hardness 0°f)............................0.64 m
Peak (residual hardness 10°f, 30% mixing) .....0.83 m
Softening.............................................. 8 ...................... 15 .................... 20 ....................30
Number of people .............................................1-2 ........................3-4 ........................5-6........................7-8
Capacity & salt consumption for the different salt dosage setting (3 bar inlet dynamic pressure)
Softener
Salt dosage (g/L of resin)
Salt amount per regen (kg)
Softener capacity [°Fm3]
Minimum of water to refill for brine preparation at 120 g/L (L)
Total approximative water usage per regeneration (L)
Softener
Salt dosage (g/L of resin)
Salt amount per regen (kg)
Softener capacity [°Fm3]
Minimum of water to refill for brine preparation at 120 g/L (L)
Total approximative water usage per regeneration (L)
Softener connections
Inlet/Outlet........................................................1"
Drain line ..........................................................½" O.D.
Overflow drain line............................................½"
Electrical
Transformer input voltage................................100-240 VAC 50/60 Hz
Softener max. power consumption ..................6 W
Protection rating...............................................IP 20
Transient overvoltages .....................................within the limits of category II
Pollution Degree...............................................3
Temporary overvoltages must be limited in duration and in frequency.
8 / 116
3
3
/h .............0.60 m
/h .............0.88 m
3
3
/h .............0.78 m
/h .............1.14 m
3
3
/h .............1.20 m
/h .............1.76 m
3
3
/h .............1.56 m
/h .............2.29 m
Evolio 5800 SXT 8
Evolio 5800 SXT 20
3
/h .............1.20 m
3
/h .............1.56 m
3
/h .............2.40 m
3
/h .............3.12 m
Evolio 5800 SXT 15
120
0.96
40.2
2.7
49.9
Evolio 5800 SXT 30
120
2.64
110.4
7.4
121.8
Ref. MKT-UG-039 / A - 01.04.2020
3
/h
3
/h
3
/h
3
/h
120
1.80
75.3
5.0
89.3
120
3.60
150.6
10.1
173.9