Power-Up Routine

After power is connected to the dome, the dome
performs the following homing routine.
1. After a few seconds, the camera lens tilts up
into the housing and eyeball assembly.
2. The lens tilts downs until it looks at the floor.
3. Eyeball pans slowly.
4. Lens tilts up 90° (home position).
Once the lens is in its home position, you can then
use the controller to call up the camera and control it.

Synchronizing Domes

To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to a 50Hz or 60Hz ac source. A V-phase
adjustment at the control console enables the
dome to sync to any line phase.

Diagnostic LEDs

If a base without I/O board is used, LEDs in the
housing and eyeball assembly enable you to check
for power and data.
If a base with I/O board is used, LEDs on the
underside of the mounting base enable you to
check for power and data. If an RS-422 network is
used, other LEDs on the board indicate that wiring
is correct, reversed, open, or grounded.
SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME
INSTALLATION AND SERVICE GUIDE

Warnings and Cautions

Please review the following warnings and cautions
before you begin installation or service.
WARNINGS
!
WARNING!
ALWAYS USE:
• Proper safety equipment for the location and
type of installation.
• Proper lift equipment to reach the installation.
• Safety features of the lift equipment.
BE SURE:
• Electrical power is not connected to the dome
when connecting wires. Dome will move when
power is applied.
• Electrical power is not connected to nearby
fixtures that you might touch during installation.
!
WARNING!
DO NOT install this camera dome where highly
combustible or explosive products are stored or
used.
!
WARNING!
This dome runs on 24Vac. DO NOT connect line
voltage to this dome.
North America power requirements: In North
America, this device is intended to be supplied
from a Class 2 power supply. For outdoor
installations, use Class 3 wiring techniques, liquid-
tight conduit, or liquid-tight pipe.
This installation should be made by a qualified
service person and should conform to all local
codes.