Manchester: After approximately 20 seconds, the three LEDs do the following:
Red
Green
Blinking
Steady,
Blinking, then
1
Steady
Blinking
Steady, then
Blinking
RS-422: Set the domes address switches to 900 test mode, then apply power.
After approximately 20 seconds, the three LEDs do the following:
Red
Green
Mostly Off,
Mostly Off,
Blinking On
Blinking On
Mostly Off,
Mostly Off,
Blinking On
Blinking On
Mostly On,
Mostly On,
Blinking Off
Blinking Off
Off
On
3
When not in address 900 test mode.
When done testing, reset the address switches back to the camera address.
SensorNet: After approximately 20 seconds, the three LEDs do the following:
Red
Green
Blinking
Steady, then
Rapidly
Blinking
Blinking
Steady, then
Rapidly
Blinking
Blinking
Steady, then
Rapidly
Blinking
Blinking
Steady, then
Blinking
SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME
INSTALLATION AND SERVICE GUIDE
Yellow
2
Steady, then Off
Steady
Yellow
Rapidly Blinking
Rapidly Blinking
Rapidly Blinking
Alternating Off and On
Every 60 Sec.
Yellow
Control
4
Steady, then Off
5
Steady, then Off
Steady
Steady
16 of 37
Possible Cause
White (pin1) and black (pin 2) correctly wired.
1
When the network has been detected.
2
When data for this dome has been received. Thereafter,
the yellow LED will flicker when data is sent to this dome.
White (pin 1) or white and black (pin 2) wires not connected,
or white and black wires shorted.
3
Possible Cause
Control
Yes
RX+ (pin 6) and RX– (pin 7) correctly wired.
No
Wire to RX+ (pin 6) not connected.
No
Wires to RX+ (pin 6) and RX– (pin 7) reversed.
No
Wire to RX– (pin 7) not connected.
Wires to RX+ or RX– not connected or shorted
together.
Wires to RX+ and/or RX– shorted to ac ground.
Possible Cause
Yes
Pins 1 and 2 correctly wired.
4
When data for this dome is received.
Thereafter, the yellow LED will flicker when data
is sent to this dome.
No
Wires to pin 1 and/or pin 2 shorted to ac ground.
5
When data for this dome is received.
No
Wire to pin 2 not connected.
No
Wires to pins 1 and 2 shorted together.
Wire to pin 1 not connected or both wires to pins
1 and 2 not connected.