Example 2. Assume that 3 types of alarm occur for one
particular channel. Video-Loss has highest priority, followed by
Alarm-In and Motion-Detection. In other words, Alarm-In A1
can trigger another alarm during the Motion-Detect M1 alarm,
and Video-Loss V1 can trigger another alarm during the
Alarm-In A1 alarm. Motion-Detect M2 is however ignored
during the Video-Loss-V1 alarm, and Motion- Detect M3 is
ignored during the release time delay for the Alarm-In A2
alarm.
44
Motion-Detect
Trigger
M1
Alarm-In
Trigger
A 1
Video-Loss
Trigger
V 1 V 2
M1 A 1
Result
M4
M2
M3
A 2
2 Sec
2 Sec
V 1
A 2