Setting the Control Protocol of the
Display Controller
Change the settings for the control protocol on
the Advanced Menu. Entered values will not be
applied unless you click on [Apply].
1
Set ADCP.
ADCP Service setting area
ADCP button
Start ADCP Service: Set ADCP to enabled or
disabled. Items for ADCP are enabled only
when this function is enabled.
-Requires Authentication: Set the
authentication for ADCP to enabled or
disabled. The password is the same as
that of the Web page administrator.
-Port No.: Input the server port of ADCP. The
factory default setting is "53595."
-TimeOut: Input the time (seconds) until
ADCP communication is terminated in
case it is disconnected. The factory
default setting is "60."
-Host Address: Input the IP address that the
ADCP server is allowed to receive. If no IP
address is input, receiving commands will
be allowed from any IP address. From the
moment the IP address is input, access
will be allowed only from that input IP
address. For security reasons, it is
recommended to input an IP address to
restrict access.
2
Press the LED Control API button to open
the LED Control API page.
LED Control API Service setting area
LED Control API button
Start LED Control API Service: Set the LED
Control API function on or off. The factory
default setting is off.
Requires Authentication: Set the LED
Control API authentication function on or
off.
PSK (Pre-Shared Key) (for authentication):
Enter the PSK (Pre-Shared Key). Only a
string alphanumeric characters with a
length of 8 to 63 characters can be
entered.