Wiring example

When using several front-door stations within one system:
Use the R-terminal to connect a door release relay.

2-wire special operation

In this operation mode, only one front-door station can
be connected! One P-wire is to be build by a jumper
between terminal a and P.
Note: The front-door station is not working, if the jumper is set at
b instead at a.
 Install the devices of the system completely.
 Check the a, b and P wire against each other for short-circuits.
 Switch on the mains voltage.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129  Mail: info@tcsag.de
7

Commissioning

Subject to technical changes.